Model 1260 |
|
High impedance Volume Control with 12 position light touch rotary silent switch. Top volume position shows the amplifiera minimum of twice the impedance of the speaker.
- Allows attenuation or balancing of amplifier volume to one pair of speakers.
- Handles high current from amplifiers (to 90W/ch RMS).
- Total attenuation -42dB, full clockwise position is direct connection to amplifier, counter clockwise is off.
- Per step attenuation: -3dB top seven steps, -6dB lower 4, last step off.
- Mounting requirements: fits all single-gang backless retrofit boxes and standard plaster rings. Mounting depth: 3" (76mm) from finished wall.
- Dimensions: 1 1/2" x 4" x 3" (38mm x 102mm x 76mm).
- Speaker impedance: 4"-8".
- Amplifier impedance: (8" speaker) 2 x 16", 4 x 32", 8 x 64", 16 x 128". (4"speaker) 2 x 8", 4 x 16", 8 x 32", 16 x 64".
- Terminal type locked-screw quick disconnect 20-14 AWG wire capacity.
- Frequency response: 20 Hz-20 kHz �1dB.
- Power rating: 90 RMS max input/channel.
Level adjustments of high and/or mid frequencies address reflectiveness or peakiness in the room environment. Our high quality ceramic level controls and discrete multi-step resistive dividers utilize low distortion metal-oxide resistors.
|